History Firmware CAN 300 PRO (700-600-CAN12) ============================================ V1.60 05.08.2016 - Overflow bit in PLC will be supported again - CANopen master behavior adapted for older handling block versions - RxPDO image will be irgnored without projected RxPDOs in the CANopen master project V1.46 25.02.2015 - SDO downloads >255 now available - improved dectection of the NMT status - fixed MMC initialization issue - SF-LED shows error when copying project to MMC fails - implementation of layer 2 block transmission - activation of the CAN monitor by a missing response to RTRs inhibited - revised start-up behavior of the CANopen master - revised CANopen monitoring V1.36 10.12.2012 - Serial layer 2 communication is included. - Bug with project length is fixed. - Command console was extended (firmware date, AG monitor filter). V1.34 12.01.2012 - Fixed the Highprior bit problem of the received frames (29 Bit) in the PLC - Implented transparent layer 2 communication via serial port V1.32 08.08.2011 - Nodeguarding problem bug fixed regarding the garding time and loading state of the FIFO - protokoll printing added to the master - master status added to the livelist - if the EFlag register is not null, the BF LED is on now V1.28 29.04.2011 - Master behavior changed for node guarding monitoring when a slave got lost - Status of the RTR bit in the COB-ID of the TxPDOs of the slaves is no longer ignored by the master V1.24 01.07.2010 - Master behavior changed for disable and enable of slaves by the PLC - Improvment of the using of any COB IDs for the PDOs up 0x0181 to 0x57F - command ".agmon" extend with options for the DS31 port V1.21 03.05.2010 - Sync telegrams generated by FB28 in the PLC are now valid for all Transmission Types (0-240) - Inhibit Time can now also be configured for TxPDOs - BF LED automatically turns off when no further errors occur for a certain time - after a state change request the master will no longer perfrom nodeguarding if monitoring is disabled for this slave - slaves without any monitoring cannot be set as a mandatory device - a performance statistic can now be requested via CANParam V4.20 and later - communication handling and speed improved V1.11 23.11.2009 - during start-up the master automatically activates all projected PDOs in the slave - object indicies of the activated PDOs are now adopted from the project - SDOs with command specifier 0x42 (unidentified data type) are now accepted V1.08 24.06.2009 - CANopen Master: Power-LED flashing if not "operational" - SDO communication stability improved - corrected problems on project download - abort of project download problem corrected V1.03 27.03.2009 - minor corrections in communication stability - optimised SDO communication V1.00 12.03.2009 - 1. Release